Articles

Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates

Volume 50 · Issue 6 · January 2016 Publish Date: February 7, 2020
Full Text PDF
DOI
Adnan Kara
Haluk Celik
Yunus Oc
Metin Uzun
Mehmet Erdil
Cihangir Tetik
Kara, A., Celik, H., Oc, Y., Uzun, M., Erdil, M., & Tetik, C. (2020). Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Acta Orthopaedica Et Traumatologica Turcica, 50(6), 665–669. https://doi.org/10.1016/j.aott.2016.04.001
Full Text Full Text PDF

Abstract

Objective: Anatomic volar rim locking plates are designed with the aim of treating intraarticular distal radius fractures. When used to treat comminuted distal radius fractures, these plates can damage the flexor tendons. In this study, we sought to determine the radiological and functional results and rate of complications of these plates.

Methods: We retrospectively reviewed the records of 36 patients (28 males, 8 females; mean age: 46.4 years) with AO/OTA Type C2-C3 distal radius fractures treated with anatomic volar rim distal radius plates between January 2011 and December 2014. Radial length, radial inclination and palmar tilt were compared with the intact wrist. Results were evaluated with the Mayo wrist and Lidstrom scores. Complications were documented throughout the follow-up period of 23.8 (range: 12 to 48) months.

Results: Postoperative measurements of the radial length, inclination and palmar tilt did not differ significantly. Mayo wrist and Lidstrom scores were good and excellent in 27 and 32 patients, respectively. Flexor tenosynovitis was symptomatic in 15 patients and asymptomatic (localized swelling only) in 21. Plates were removed from 15 patients due to symptomatic tenosynovitis and from six patients due to partial rupture of the flexor pollicis longus tendon. The flexor digitorum profundus tendon of the second finger was also partially ruptured in three patients.

Conclusion: Anatomic volar rim locking plates provide satisfying radiological and functional results in treating AO/OTA Type C2-C3 comminuted distal radius fractures. However, if these plates interfere with the union of the fracture, they should be removed to avoid potential tendon problems caused by their placement in the rim region.

Level of Evidence: Level IV, Therapeutic study

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 50 · Issue 6 · January 2016
Pages 665-669
History
Published Online February 7, 2020
Copyright
Affiliations
1
Adnan Kara
2
Haluk Celik
3
Yunus Oc
4
Metin Uzun
5
Mehmet Erdil
6
Cihangir Tetik
Cite this Article
Kara, A., Celik, H., Oc, Y., Uzun, M., Erdil, M., & Tetik, C. (2020). Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Acta Orthopaedica Et Traumatologica Turcica, 50(6), 665–669. https://doi.org/10.1016/j.aott.2016.04.001
Share
Outlines