Articles

The quality of life analysis of knee prosthesis with complete microprocessor control in trans-femoral amputees

Volume 51 · Issue 6 · January 2017 Publish Date: February 6, 2020
Full Text PDF
DOI
Yavuz SAGLAM
Baris GULENC
Fevzi BİRİSİK
Ali ERSEN
Ebru Yilmaz YALCİNKAYA
Onder YAZİCİOGLU
SAGLAM, Y., GULENC, B., BİRİSİK, F., ERSEN, A., Yilmaz YALCİNKAYA, E., & YAZİCİOGLU, O. (2020). The quality of life analysis of knee prosthesis with complete microprocessor control in trans-femoral amputees . Acta Orthopaedica Et Traumatologica Turcica, 51(6), 466–469. https://doi.org/10.1016/j.aott.2017.10.009
Full Text Full Text PDF

Abstract

Abstract


The aim of this study was to analyze the patient demographics, etiology of limb loss as well as reporting SF-36 scores for microprocessor prosthesis users in Turkish population. We reviewed 72 patients (61 male and 11 female; mean age: 37.7 ± 10.7) with uni-lateral, above knee amputation and a history of regular and microprocessor prosthesis use. All patients were called back for a last follow-up and they were asked to fill a self-administered general health status questionnaire (SF-36). According to the SF-36 results; physical component score (PCS) score was 46 ± 7.3 and mental components summary (MCS) score was 46.5 ± 9.1. These scores have statistical similarity with Turkish healthy controls, except SF (social functioning) sub-dimension. PCS score for women microprocessor users were significantly lower than men (43.3 vs. 48.7, p = 0.03), but MCS scores were similar in between genders (46 vs. 48.2, p = 0.13). Conventional prostheses usage time was positively correlated with physical function (PF) scores (r = 0.322, p = 0.010). Microprocessor prosthesis usage time was negatively correlated with role limitations due to emotional problem (RE) scores (r = -0,313, p = 0.009). The quality of life surveys were showed that the loss of an extremity have higher physical and psychological impact on women's physical scores. Overall, SF-36 results were similar in microprocessor using amputee's and Turkish normal controls. Level IV, therapeutic study.
ER -

Keywords

  • Trans-femoral amputees
  • Microprocessor controlled prosthesis
  • Quality of life analysis
  • Physical component summary score

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 51 · Issue 6 · January 2017
Pages 466-469
History
Published Online February 6, 2020
Copyright
Affiliations
1
Yavuz SAGLAM
2
Baris GULENC
3
Fevzi BİRİSİK
4
Ali ERSEN
5
Ebru Yilmaz YALCİNKAYA
6
Onder YAZİCİOGLU
Cite this Article
SAGLAM, Y., GULENC, B., BİRİSİK, F., ERSEN, A., Yilmaz YALCİNKAYA, E., & YAZİCİOGLU, O. (2020). The quality of life analysis of knee prosthesis with complete microprocessor control in trans-femoral amputees . Acta Orthopaedica Et Traumatologica Turcica, 51(6), 466–469. https://doi.org/10.1016/j.aott.2017.10.009
Share
Outlines