Articles

Isotretinoin induced achilles tendinopathy: Histopathological and biomechanical evaluation on rats

Volume 52 · Issue 5 · January 2018 Publish Date: February 6, 2020
Full Text PDF
DOI
Ozan BEYTEMÜR
Serdar YÜKSEL
Ümit Seza TETİKKURT
Erdinç GENÇ
Ercan OLCAY
Akif GÜLEÇ
BEYTEMÜR, O., YÜKSEL, S., Seza TETİKKURT, Ümit, GENÇ, E., OLCAY, E., & GÜLEÇ, A. (2020). Isotretinoin induced achilles tendinopathy: Histopathological and biomechanical evaluation on rats . Acta Orthopaedica Et Traumatologica Turcica, 52(5), 387–391. https://doi.org/10.1016/j.aott.2018.06.006
Full Text Full Text PDF

Abstract

Abstract

Objective
The aim of the present study was to evaluate histopathological and biomechanical effects of isotretinoin on Achilles tendon.
Materials & methods
Sixteen rats were divided into two groups including the control group (n = 8) and isotretinoin group (n = 8). The control group received 1.42 ml/kg soy oil per day whereas the isotretinoin group received 15 mg/kg/day (gavage dose 1.42 ml/kg) isotretinoin dissolved in soy oil through gavage method for 6 weeks. Achilles tendons were excised at the end of week 6. The tendon samples were evaluated by hematoxylin-eosin under a light microscope. Quantitative evaluation was performed via Movin and Bonar scoring. A computer-monitored tensile testing machine was utilised for biomechanical testing. Biomechanical characteristics of the tendon samples (elastic modulus, yield force, ultimate tensile force) were measured.
Results
Histopathological evaluation revealed a significantly higher Movin and Bonar scores in histopathological evaluation. Movin score in isotretinoin group was 4.1 ± 2.5 and it was 2.3 ± 1.0 in control group (p = 0.032). Bonar score in isotretinoin group was 2.9 ± 1.4 and it was 1.6 ± 0.7 in control group (p = 0.022). In line with histopathological evaluation, biomechanical measurements in isotretinoin group (elastic modulus, yield force, ultimate tensile force) were significantly lower than the control group. Elastic modulus in isotretinoin group was 227 ± 27.7 N/mm2 and in control group it was 281.7 ± 38.7 N/mm2 (p = 0.006). In isotretinoin group; yield force was 33.7 ± 4.3 Pa and in control group it was 40.8 ± 5.9 Pa (p = 0.021). Ultimate tensile force in isotretinoin group was 35.7 ± 4.2 Pa and in control group it was 44 ± 7 Pa (p = 0.009).
Conclusion
The present study detected histopathological and biomechanical negative effect of isotretinoin on Achilles tendon. Therefore, isotretinoin should be questioned in medical history of patients with tendinopathy.
ER -

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 52 · Issue 5 · January 2018
Pages 387-391
History
Published Online February 6, 2020
Copyright
Affiliations
1
Ozan BEYTEMÜR
2
Serdar YÜKSEL
3
Ümit Seza TETİKKURT
4
Erdinç GENÇ
5
Ercan OLCAY
6
Akif GÜLEÇ
Cite this Article
BEYTEMÜR, O., YÜKSEL, S., Seza TETİKKURT, Ümit, GENÇ, E., OLCAY, E., & GÜLEÇ, A. (2020). Isotretinoin induced achilles tendinopathy: Histopathological and biomechanical evaluation on rats . Acta Orthopaedica Et Traumatologica Turcica, 52(5), 387–391. https://doi.org/10.1016/j.aott.2018.06.006
Share
Outlines