Research Article

Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis

Volume 55 · Issue 1 · January 2021 Publish Date: February 22, 2021
Full Text PDF
DOI
Jun Zhang
Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China
Yan Wei
Department of Surgery, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
Guoding Li
Department of Orthopaedics, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
Jian Wang
Department of Orthopaedics, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
Youjia Xu
Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China
Zhang, J., Wei, Y., Li, G., Wang, J., & Xu, Y. (2021). Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis. Acta Orthopaedica Et Traumatologica Turcica, 55(1), 9–15. https://doi.org/10.5152/j.aott.2021.20035
Full Text Full Text PDF

Abstract

Objective: The aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two different working lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.

Methods: From the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated; the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groups A and B). Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA. Two loading conditions (axial compression and torsion) were applied at the center of the femoral head. Construct stiffness, interfragmentary micromotion, and the peak von Mises stress (VMS) on the plate were assessed.

Results: Group D provided the highest axial stiffness (1347 N/mm), and group A was the weakest (439 N/mm). With the lag screw, shear micromotion remained generally low compared with that without the screw for all axial and torsional load levels and for both plate working lengths, i.e., 0.23 mm with lag screw versus 0.43 mm without lag screw (102 mm working length, 700 N). The percentage decreases of shear micromotion under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >22% and 73%, respectively; while those for the 82-mm working length were >28% and 33%, respectively. The reduction of axial micromotion was observed with the lag screw for all axial load levels as well as for both plate working lengths, i.e., 0.33 mm with lag screw versus 0.87 mm without lag screw (102-mm working length, 700 N). The percentage decreases of axial micromotion under axial loading (350/700/1400 N) for 102 mm and 82 mm working lengths were >42% and 50%, respectively. The peak VMS on the plate stayed generally low with lag screw compared with without lag screw throughout all tested load levels, as well as for both plate working lengths, i.e., 124.26 MPa versus 244.39 MPa (102 mm working length, 700 N). The percentage decreases of the peak VMS under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >40% and 69%, respectively, while those for the 82-mm working length were >47% and 61%, respectively.

Conclusion: The current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct provides better torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally, the strength of the materials is increased and implant failure can be minimized by using this technique.

Cite this article as: Zhang J, Wei Y, Li G, Wang J, Xu Y. Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis. Acta Orthop Traumatol Turc 2021; 55(1): 9-15.

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 55 · Issue 1 · January 2021
Pages 9-15
History
Published Online February 22, 2021
Copyright
Affiliations
1
Jun Zhang
Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China
2
Yan Wei
Department of Surgery, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
3
Guoding Li
Department of Orthopaedics, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
4
Jian Wang
Department of Orthopaedics, Pudong New Area People’s Hospital affiliated to Shanghai University of Medicine & Health Sciences, Shanghai, China
5
Youjia Xu
Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China
Cite this Article
Zhang, J., Wei, Y., Li, G., Wang, J., & Xu, Y. (2021). Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis. Acta Orthopaedica Et Traumatologica Turcica, 55(1), 9–15. https://doi.org/10.5152/j.aott.2021.20035
Outlines