Intraoperative lateral wall breach simulation in the cadaveric spine and the impact of thread designs of screws on pullout strength in the osteoporotic thoracic vertebrae: A biomechanical study in human cadavers

Volume 58 · Issue 1 · January 2024 Publish Date: February 28, 2024
Full Text PDF
DOI
Ozcan Kaya
Department of Orthopedics and Traumatology, Istanbul Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Turkey
Okan Ozkunt
Department of Orthopedics and Traumatology, Medicana Istanbul Bahçelievler Hospital, Istanbul, Turkey
Mustafa Sungur
Department of Orthopedics and Traumatology, Acıbadem MAA University, School of Medicine, Istanbul, Turkey
Mehmet Semih Cakir
Department of Interventional Radiology, Istanbul University, Istanbul Faculty of Medicine, Istanbul, Turkey
Murat Baydogan
Istanbul Technical University, Istanbul, Turkey
Kerim Sariyilmaz
Department of Orthopedics and Traumatology, Acıbadem MAA University, School of Medicine, Istanbul, Turkey
Kaya, O., Ozkunt, O., Sungur, M., Cakir, M. S., Baydogan, M., & Sariyilmaz, K. (2024). Intraoperative lateral wall breach simulation in the cadaveric spine and the impact of thread designs of screws on pullout strength in the osteoporotic thoracic vertebrae: A biomechanical study in human cadavers. Acta Orthopaedica Et Traumatologica Turcica, 58(1), 57–61. https://doi.org/10.5152/j.aott.2024.22067
Full Text Full Text PDF

Abstract

Objective: This study aimed (1) to simulate pedicle screw pullout after intraoperative external wall perforation and (2) to assess restoration strength with different thread designs in the pedicle screw instrumentation for osteoporotic thoracic vertebrae.

Methods: Twenty fresh-frozen human cadaveric thoracic vertebra bodies were prepared and divided into 4 groups: group 1, 5.5 mm × 45 mm polyaxial single thread pedicle screws (PASTS); group 2, after wall injury 5.5 mm × 45 mm PASTS; group 3, 6.5 mm × 45 mm PASTS after wall injury; and group 4: 6.5 mm × 45 mm polyaxial mixed-threaded screws after wall injury. While group 1 was the control group, groups 2, 3, and 4 were used as study groups after the lateral wall breach. All prepared screw units were placed on a universal pullout measurement testing device.

Results: The mean bone mineral density for 20 thoracic vertebrae was 0.57 ± 0.12 g/cm2 (range 0.53-0.6 g/cm2 ). The mean pullout strength was 474.90 Newtons (N) for group 1, 412.85 N for group 2, 475.4 N for group 3, and 630.74N for group 4. The lateral wall breach caused a 14.1 % decrease in average pullout strength compared with the initial screw pullout. Mixed (double)-threaded screws increased pullout strength compared to 6.5 mm screws (P=.036)

Conclusion: Using a 1 mm thicker polyaxial pedicle screw or mixed (double)-threaded pedicle screw seems to increase pullout strength; however, this was statistically significant only for group 4. In the thoracic spine, the redirection possibility of the pedicle screw is limited, and augmentation with cement will not be appropriate due to the risk of wall injury-related leakage. Therefore, care should be taken to avoid violating the lateral cortex by using appropriate pedicle entry points and trajectories.

Cite this article as: Kaya O, Ozkunt O, Sungur M, Cakir MS, Baydogan M, Sariyilmaz K. Intraoperative lateral wall breach simulation in the cadaveric spine and the impact of thread designs of screws on pullout strength in the osteoporotic thoracic vertebrae: A biomechanical study in human cadavers. Acta Orthop Traumatol Turc., 2024;58(1):57-61.

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 58 · Issue 1 · January 2024
Pages 57-61
History
Published Online February 28, 2024
Copyright
Affiliations
1
Ozcan Kaya
Department of Orthopedics and Traumatology, Istanbul Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Turkey
2
Okan Ozkunt
Department of Orthopedics and Traumatology, Medicana Istanbul Bahçelievler Hospital, Istanbul, Turkey
3
Mustafa Sungur
Department of Orthopedics and Traumatology, Acıbadem MAA University, School of Medicine, Istanbul, Turkey
4
Mehmet Semih Cakir
Department of Interventional Radiology, Istanbul University, Istanbul Faculty of Medicine, Istanbul, Turkey
5
Murat Baydogan
Istanbul Technical University, Istanbul, Turkey
6
Kerim Sariyilmaz
Department of Orthopedics and Traumatology, Acıbadem MAA University, School of Medicine, Istanbul, Turkey
Cite this Article
Kaya, O., Ozkunt, O., Sungur, M., Cakir, M. S., Baydogan, M., & Sariyilmaz, K. (2024). Intraoperative lateral wall breach simulation in the cadaveric spine and the impact of thread designs of screws on pullout strength in the osteoporotic thoracic vertebrae: A biomechanical study in human cadavers. Acta Orthopaedica Et Traumatologica Turcica, 58(1), 57–61. https://doi.org/10.5152/j.aott.2024.22067
Outlines