Research Article

Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther

Volume 60 · Issue 1 · February 2026 Publish Date: February 26, 2026
Full Text PDF
DOI
Abdurrahman Yılmaz ORCID
Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye
Turab Selçuk ORCID
Department of Electrical & Electronics Engineering, Kahramanmaraş Sütçü İmam University, Türkiye
Taha Aksoy ORCID
University of Miami, Florida, United States
Bülent Atilla ORCID
Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye
Yılmaz, A., Selçuk, T., Aksoy, T., & Atilla, B. (2026). Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthopaedica Et Traumatologica Turcica, 60(1). https://doi.org/10.5152/j.aott.2026.25268
Full Text Full text PDF

Abstract

Objective: The anteroposterior (AP) pelvic X-ray is commonly used for assessing conditions affecting the bony pelvis. The objective of this study was to develop new pelvic X-ray assessment software (CalculOrther) to assess AP pelvic X-rays and evaluate its reliability. 

Methods: CalculOrther was developed in 4 stages. Initially, a dataset comprising pelvic X-rays was generated. During the second stage, the convolutional neural network model was trained to identify anatomical landmarks in the pelvic X-ray images. The Hough transform was used to locate the circle and center of the femoral head in the third stage. The border pixels were generated using mathematical morphological processes, and the requisite angles were measured in the fourth stage. Then manual measurements and the software developed were analyzed with Pearson’s correlation and intraobserver and interobserver correlation coefficients. Subsequently, the mean error and the root mean square error (RMSE) were acquired. 

Results: The Pearson’s correlation coefficients varied from 0.84 to 0.99 (P < .001). The interobserver and intraobserver correlation coefficients ranged from 0.77 to 0.99 and from 0.75 to 0.94, respectively. The RMSE ranged from 0.31 to 4.38 and the mean error from 0.05 to 2.86. The mean duration for manual measurements was 230 (177-284) seconds and 215 (160-255) seconds, respectively. The software required an average time of 3.18 (2.95-3.52) seconds to make the same measurements. 

Conclusion: Regarding femoroacetabular impingement and hip dysplasia, artificial intelligence can analyze pelvic radiographs and generate equally accurate results within a shorter duration compared to traditional measuring methods. 

 

 

Cite this article as: Yilmaz A, Selcuk T, Aksoy T, Atilla B. Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthop Traumatol Turc., 2026; 60(1), 0268, doi: 10.5152/j.aott.2026.25268

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 60 · Issue 1 · February 2026
History
Published Online February 26, 2026
Copyright
Affiliations
1
Abdurrahman Yılmaz ORCID
Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye
2
Turab Selçuk ORCID
Department of Electrical & Electronics Engineering, Kahramanmaraş Sütçü İmam University, Türkiye
3
Taha Aksoy ORCID
University of Miami, Florida, United States
4
Bülent Atilla ORCID
Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye
Cite this Article
Yılmaz, A., Selçuk, T., Aksoy, T., & Atilla, B. (2026). Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthopaedica Et Traumatologica Turcica, 60(1). https://doi.org/10.5152/j.aott.2026.25268
Outlines