Research Article

Comparison of Kirschner wire versus volar locking plate fixation for distal radius fractures: clinical and functional outcomes

Volume 60 · Issue 2 · March 2026 Publish Date: March 12, 2026
Full Text PDF
DOI
Okan Yiğit ORCID
Department of Orthopaedic Surgery and Traumatology, Kartal Dr. Lütfi Kırdar City Hospital, İstanbul, Türkiye
Hayati Kart ORCID
Department of Orthopaedic Surgery and Traumatology, Göztepe Training and Research Hospital, İstanbul, Türkiye
Görkem Çat ORCID
Orthopaedics and Traumatology Clinic, Bitlis State Hospital, Bitlis, Türkiye
Emrah Gökay Özgür ORCID
Department of Biostatistics, Marmara University School of Medicine, İstanbul, Türkiye
Erdem Koç ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
Veysel Burak Özmusul ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
Özgür Baysal ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
Yiğit, O., Kart, H., Çat, G., Özgür, E. G., Koç, E., Özmusul, V. B., & Baysal, Özgür. (2026). Comparison of Kirschner wire versus volar locking plate fixation for distal radius fractures: clinical and functional outcomes. Acta Orthopaedica Et Traumatologica Turcica, 60(2). https://doi.org/10.5152/j.aott.2026.25585
Full Text Full text PDF

Abstract

Objective: This study aimed to compare the clinical and functional outcomes of Kirschner wire (K-wire) fixation versus volar locking plate (VLP) fixation for intra-articular distal radius fractures (DRFs). It also aimed to identify key patient- and fracture-related factors that influence the choice of surgical technique and to evaluate the responsiveness of specific patient-reported outcome measures in assessing recovery. 

Methods: A total of 201 consecutive patients with Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association–classified DRFs (Type A: n = 51; B: n = 90; C: n = 60) treated surgically between 2005 and 2022 were analyzed. Treatment allocation was based on fracture complexity and surgeon preference, resulting in a distribution where K-wire (n = 63) was primarily used for partial articular fractures (72.4% of K-wire cases were Type B), while VLP (n = 138) was preferred for complete articular fractures (83.6% of plate cases were Type C). Functional outcomes were assessed using Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) (primary endpoint), Green-O’Brien, Gartland–Werley, and SF-12 at standardized intervals (6/12/24 months) during supervised physiotherapy. 

Results: Significant predictors of plate fixation included older age (58.1 ± 14.7 vs. 42.3 ± 12.1 years, P < .001), polytrauma (aOR: 2.4, 95% CI: 1.5-3.8), and complete articular fractures (83.6% Type C, P = .01). No statistically significant associations were found between injury type and fixation method (P = .20) or between complications and fixation method (4.8% vs. 2.2%, P = .41). Functional outcomes were comparable across all metrics, with no statistically significant differences observed: QuickDASH (34.9 ± 18.2 K-wire vs. 31.2 ± 16.8 plate, P = .146), Green-O’Brien (excellent-good: 76.2% vs. 82.6%, P = .552), Gartland–Werley (78.1% vs. 71.1% excellent-good, P = .591), and 12-Item Short Form Health Survey (SF-12) (100% vs. 99.3% good results, P = .32). Multivariable regression identified reduction quality (β = 0.81, P < .01), not implant type, as the primary outcome determinant. 

Conclusion: This study suggests that anatomical reduction quality—not fixation method—is the primary determinant of functional success in DRFs, with both K-wire and VLP achieving comparable outcomes (QuickDASH/Gartland–Werley P > .05). K-wires represent a cost-effective alternative for partial articular fractures (72.4% of cases), while plates were more frequently used in complex fractures and polytrauma cases (adjusted odds ratio [aOR] = 2.4). Early rehabilitation (median 4 days post-op) and condition-specific metrics (QuickDASH, Green-O’Brien) are critical for optimal recovery, whereas SF-12 proves less sensitive for wrist-specific assessment. These findings advocate for surgeon-tailored technique selection based on fracture pattern and emphasize the need for multicenter randomized controlled trials (RCTs) to evaluate long-term outcomes. 

 

Cite this article as: Yigit O, Kart H, Cat G, et al. Comparison of Kirschner wire versus volar locking plate fixation for distal radius fractures: clinical and functional outcomes. Acta Orthop Traumatol Turc. 2026; 60(2), 0585, doi: 10.5152/j.aott.2026.25585. 

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 60 · Issue 2 · March 2026
History
Published Online March 12, 2026
Copyright
Affiliations
1
Okan Yiğit ORCID
Department of Orthopaedic Surgery and Traumatology, Kartal Dr. Lütfi Kırdar City Hospital, İstanbul, Türkiye
2
Hayati Kart ORCID
Department of Orthopaedic Surgery and Traumatology, Göztepe Training and Research Hospital, İstanbul, Türkiye
3
Görkem Çat ORCID
Orthopaedics and Traumatology Clinic, Bitlis State Hospital, Bitlis, Türkiye
4
Emrah Gökay Özgür ORCID
Department of Biostatistics, Marmara University School of Medicine, İstanbul, Türkiye
5
Erdem Koç ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
6
Veysel Burak Özmusul ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
7
Özgür Baysal ORCID
Department of Orthopaedic Surgery and Traumatology, Marmara University, Pendik Training and Research Hospital, İstanbul, Türkiye
Cite this Article
Yiğit, O., Kart, H., Çat, G., Özgür, E. G., Koç, E., Özmusul, V. B., & Baysal, Özgür. (2026). Comparison of Kirschner wire versus volar locking plate fixation for distal radius fractures: clinical and functional outcomes. Acta Orthopaedica Et Traumatologica Turcica, 60(2). https://doi.org/10.5152/j.aott.2026.25585
Outlines