Research Article

Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems

Volume 60 · Issue 5 · September 2026 Publish Date: October 7, 2026
Full Text PDF
DOI
İsa Bolat ORCID
Department of Orthopaedics and Traumatology, Dörtyol State Hospital, Hatay, Türkiye
Mustafa Tekin ORCID
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye
Jalal İbrahimov ORCID
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye
Orçin Bozkurt ORCID
Department of Orthopaedics and Traumatology, Karşıyaka State Hospital, Adana, Türkiye
Bolat, İsa, Tekin, M., İbrahimov, J., & Bozkurt, O. (2026). Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems. Acta Orthopaedica Et Traumatologica Turcica, 60(5). https://doi.org/10.5152/j.aott.2026.25811
Full Text Full text PDF

Abstract

Objective: This study aimed to evaluate the accuracy of standardized preoperative radiographic templating in predicting femoral and tibial component sizes across four different total knee arthroplasty (TKA) systems in patients undergoing primary TKA for osteoarthritis.

Methods: This retrospective, single-center observational study included 160 knees from 141 patients (mean age of 67.3 - 7.9 years) who underwent primary TKA for osteoarthritis between March 2011 and March 2020. Of the 141 patients, 122 underwent unilateral and 19 underwent bilateral TKA. Four different TKA systems were evaluated, with 40 knees assigned to each implant group. Standardized weight-bearing anteroposterior and lateral knee radiographs were used to measure femoral and tibial dimensions using a picture archiving and communication system (PACS). The primary outcome was the agreement between radiographically predicted and intraoperatively implanted femoral and tibial component sizes. Agreement was assessed using weighted Cohen’s kappa (κ), and interobserver reliability was evaluated using the intraclass correlation coefficient (ICC).

Results: For femoral components, the exact size was predicted in 76.9% of knees, and 96.8% of predictions were within - 1 implant size. For tibial components, the exact size was predicted in 64.4% of knees, and 92.5% were within - 1 implant size. Agreement between predicted and implanted sizes was substantial for femoral components (κ = 0.70, 95% CI, 0.62–0.78) and moderate for tibial components (κ = 0.54, 95% CI, 0.45–0.63). Size discrepancies differed significantly among the four implant systems for both tibial (P = 0.001) and femoral components (P = 0.010). Overall, 94.4% (302/320) of all component size predictions were within - 1 implant size.

Conclusion: Standardized preoperative radiographic templating reliably predicted component size across four different TKA systems, with greater accuracy for femoral than for tibial components. When standardized radiographic acquisition, calibration, and measurement protocols are applied, conventional two-dimensional templating can provide clinically acceptable component-size predictions across different implant designs. These findings support its clinical utility as an accessible and cost-effective method for preoperative planning in primary TKA.

 

Cite this article as: Bolat İ, Tekin M, İbrahimov J, Bozkurt O. Accuracy of standardized preoperative radiographic templating in predicting implant size: a comparative analysis of four widely used total knee arthroplasty systems. Acta Orthop Traumatol Turc., 2026; 60(5), 0811, doi: 10.5152/j.aott.2026.25811.

Similar Articles

Article Info
Published In
Journal Acta Orthopaedica et Traumatologica Turcica
Volume / Issue Volume 60 · Issue 5 · September 2026
History
Published Online October 7, 2026
Copyright
Affiliations
1
İsa Bolat ORCID
Department of Orthopaedics and Traumatology, Dörtyol State Hospital, Hatay, Türkiye
2
Mustafa Tekin ORCID
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye
3
Jalal İbrahimov ORCID
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye
4
Orçin Bozkurt ORCID
Department of Orthopaedics and Traumatology, Karşıyaka State Hospital, Adana, Türkiye
Cite this Article
Bolat, İsa, Tekin, M., İbrahimov, J., & Bozkurt, O. (2026). Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems. Acta Orthopaedica Et Traumatologica Turcica, 60(5). https://doi.org/10.5152/j.aott.2026.25811
Outlines